Cubicle Fitting Instructions
Thank you for purchasing cubicles from Condon Engineering Ltd.
  • These instructions are to be used for fitting standard cantilever cubicles
  • The cubicle clamps and bolts are arranged in numbered bags. The fixings required for step 1 are located in bag no. 1, the fixings required for step no. 2 located in bag no. 2 and so on.

Single row adjustable:

NOTE: The posts (76mm) are set 250mm (10in) into the ground and 150mm (6in) from the wall. Ensure the edges of posts are positioned at least 100mm (4in) from the edge of any proposed cubicle.

STEP 1A: Attach the bottom horizontal bar (60mm pipe) 250mm (10”) from the floor to the wall side of the posts using 1no. post clamps and 2no. U-Bolts (Bag no. 1)

STEP 1B: Attach the top horizontal bar (60mm pipe) 840mm (33”) from the bottom horizontal bar to the posts using 1no. post clamps and 2no. U-Bolts (Bag no. 1)

STEP 2: Connect the cubicles to the horizontal bars using 4no. single brackets and 4no. M12x90mm nuts and bolts (Bag no. 2)

STEP 3A: Fix the headrail bar (48mm pipe) to the cubicles using 1no. headrail bracket per cubicle (Bag no. 3)

STEP 3B: Fix the headrail ends to the end walls using 2no. M12 x 80mm through bolts. (Bag no. 3)

STEP 4: Connect the headrail bar to headrail ends.